Overview

This trial is active, not recruiting.

Condition glaucoma
Sponsor Johns Hopkins University
Start date March 2011
End date March 2016
Trial size 645 participants
Trial identifier NCT01462526, NA_00044899

Summary

Current screening methods for glaucoma detection are not perfect and nearly half of those in the United States with glaucoma go undiagnosed. Minority populations are even less likely to be diagnosed. Better screening methods are needed to identify the undiagnosed and to provide them care that can help them retain good vision.

Glaucoma is often more severe in one eye and this fact can be exploited in screening tests. The investigators plan to use a novel screening device that very accurately records the pupillary response from each eye. It is likely that patients with glaucoma will have abnormal responses when measured, and by comparing responses between the two eyes the investigators will be able to determine who has glaucoma. If this test works well, it will provide a low-cost way to screen populations at risk for glaucoma. Furthermore, this research will expand the knowledge base regarding how pupil responses to light differ between persons with and without glaucoma. Insights gained from this study will be useful in the development of an effective screening tool in the detection of glaucoma.

United States No locations recruiting
Other Countries No locations recruiting

Study Design

Observational model case control
Time perspective prospective
Arm

Eligibility Criteria

Male or female participants at least 40 years old.

Inclusion Criteria: - Age 40 years or older at enrollment - Presenting visual acuity better than 20/100 in both eyes - Spherical equivalent refractive error within the range of 4.0 and -6.0 diopters in both eyes Exclusion Criteria: - Ocular surgery in either eye within 3 months

Additional Information

Official title The Detection of Glaucoma Using Pupillography
Principal investigator David S Friedman, MD
Description Glaucoma is often asymmetric in nature, and an afferent pupillary defect (APD) is frequently present in persons with glaucoma. The investigators propose to conduct a clinic-based prospective study to assess the accuracy of using a binocular pupillographic device (RAPiD, Konan Medical, USA) to detect people with glaucoma. This device is designed to record and analyze pupil responses at multiple, controlled stimulus intensities, while using varied patterns and color stimuli. The asymmetric nature of glaucoma suggests that a high proportion of persons with glaucoma will have an APD (although many may be subtle and would be missed with less refined testing methods). When glaucoma patients have severe nerve damage or when field loss is bilateral and symmetric, an APD may not be present or may be too small to detect. Noting this limitation, the investigators will compare pupillary responses to stimuli at different locations (for example the superior compared to the inferior hemifield) to determine whether the investigators can detect asymmetric glaucoma damage within the same eye. In addition, it is likely that the pupil response in glaucoma will be diminished when compared to normal, which will also help with detection. Aim1: To examine the amplitude, latency and velocity of the pupil light reflex by optimizing its measurement to stimuli of various intensities and colors, and to characterize the variability of this response in normal subjects. Aim2: To quantify the amount of structural loss (retinal nerve fiber layer thickness and optic nerve head parameters) and functional loss (visual field mean deviation) necessary for an APD (as detected by RAPiD) to manifest. Aim3a: To develop an algorithm that best discriminates those with and without glaucoma by individual or combined use of 1) detecting an APD between the two eyes, 2) comparing pupil responses in different parts of the visual field within the same eye, and 3) comparing responses of diseased eyes to responses of "normal" eyes. Aim 3b: To assess the validity of this algorithm in glaucoma detection and to assess the reproducibility of the pupil response measurements at a follow-up visit within 7 months.
Trial information was received from ClinicalTrials.gov and was last updated in November 2015.
Information provided to ClinicalTrials.gov by Johns Hopkins University.